| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | Turefull |
| Model Number : | ZF-HLB-80W-36-8c65 |
| Certification : | CE/ROHS/FCC/TUV/SAA |
| Supply Ability : | 10000 Piece/Pieces per Month |
| Price : | Negotiable |
| Payment Terms : | T/T |
| Delivery Time : | 5-10 work days |
Features
1. Adopt original imported IC,capacitor,Mos,conform to universal
standards,Stable quality and stable performance.
2. Protection:OVP/SCP/OTP/OCP
Universal input voltage design(90Vac~305Vac)
3. Output voltage and current parameters support the client
settings
4. High power factor, low harmonics
5. High efficiency design (up to 90%)
6. Protection Design: Short-circuit, over-voltage, over-temperature
7. suitable for LED Lighting
Parameter
| Model | ZF-HLB-80-36 | ZF-HLB-80-42 | ZF-HLB-80-48 | ZF-HLB-80-54 | Customized | |
| No load voltage | 37VDC | 43VDC | 49VDC | 55VDC | / |
| output current | 2.2A | 1.86A | 1.67A | 1.5A | / | |
| output power | 82W | 82W | 82W | 82W | 82W | |
| Ripple&noise | 300mV | 300mV | 300mV | 300mV | 300mV | |
| Output voltage range | 25-36VDC | 25-42VDC | 25-48VDC | 38-54VDC | / | |
| Efficiency | ≥87% | ≥87% | ≥88% | ≥88% | ≥88% | |
| Current Error | ±2% | ±2% | ±2% | ±2% | ±2% | |
| Line regulation | ±2% | ±2% | ±2% | ±2% | ±2% | |
| Load regulation | ±2% | ±2% | ±2% | ±2% | ±2% | |
| Setup,rise time | 500ms,80ms/115VAC 500ms,80ms/230VAC | |||||
| Hold up time | 16ms / 115VAC, 230VAC | |||||
| Input voltage | 90-277V | ||||
| Frequency range | 47-63HZ | |||||
| Power factory | PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC @ full load | |||||
| Total Harmonic distortion | THD< 20% (@ load≧60% / 115VAC,230VAC; @ load≧75% / 277VAC) | |||||
| AC current | 1.2A / 115VAC 0.65A / 230VAC 0.45A / 277VAC | |||||
| Inrush current | COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||
| Leakage current | <0.75mA / 277VAC | |||||
| Over current | Constant current limiting, recovers automatically after fault condition is removed | ||||
| Short circuit | Hiccup mode, recovers automatically after fault condition is removed | |||||
| Over temperature | Shut down o/p voltage, re-power on to recover | |||||
| Working Temp. | Tcase= -40 ~ +80℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section) | ||||
| Max.Case Temp. | Tcase= +80℃ | |||||
| Working Humidity | 20 ~ 95% RH non-condensing | |||||
| Temp.coefficient | ±0.03%/℃(0 ~ 60℃) | |||||
| Vibration | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||
| Safety standards | EN 61347-1:2008+A1:2011+A2:2013 ,EN 61347-2-13:2006, EN 62493:2010 | ||||
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
| Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||
| EMC emission | Compliance to EN55015, EN61000-3-2 Class C (@ load≧60%) ; EN61000-3-3,GB17743 and GB17625.1 | |||||
| EMC immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV) | |||||
| Lightning Surge | L/N-FG | ±6KV | ||||
| L-N | ±5KV | |||||
| Rubber cable | Input 3*1.0 m2 | ||||
| Rubber cable | Output 2*1.0 m2 | |||||
| Case | Full Aluminum | Silicone filled filling | ||||



|